Example:
• Configure three (3) separate autonomous host delivery streams, and divide the
module’s channels between them. Channels (1-4) must be delivered to host as
fast as possible, channels 5-8 may be delivered at half that rate, while the
remaining channels 9-16 are delivered at half the previous rate. All streams are
generated continuously and synchronized with the internal clock at 100 msec., 200
msec., and 400 msec. periods, respectively. Data are requested in single
precision binary IEEE float format f=7).
“c 00 1 000F 1 100 7 0”
“c 00 2 00F0 1 200 7 0"
“c 00 3 FF00 1 400 7 0"
Read response:
“A”
“A”
“A”
To similarly acquire data at “relative” rates (1, 2, and 4) using a periodic
hardware trigger (assumed to also cycle at 10 Hz rate), enter the commands:
“c 00 1 000F 0 1 7 0”
“c 00 2 00F0 0 2 7 0”
“c 00 3 FF00 0 4 7 0”
Read responses:
“A”
“A”
“A”
The above example is for a Model 9016 module. It would also be suitable for
Models 9021 and 9022 if no channels above 12 are scanned as in stream 3 above.
NOTE: The type of data delivered for each specified channel (when the streams are
started) is EU pressure unless sub-command “05” is also executed to select other types of
data in each stream.