Seitenansicht 105
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual
www.PressureSystems.com
3 - 76
Some special rack-mounted module types (e.g., 9816) also add rack, cluster, and slot
parameters to the response above. These additional parameters are added following the
pwrst’ parameter.
This uniform network query response allows a client host program to identify, configure,
and use any suitable group of modules (for the task at hand) by simply opening a TCP/IP connection
between itself and each available module needed.
Example:
! Query all module(s) on the network.
“psi9000”
Response(s):
200.201.7.207, 0-e0-8d-1-7-cf, 1999, 9022, 2.32, 0, 1, 9000, 192.0.0.0, 0,
1, 0x0
Seitenansicht 105